Inverter size calculator

List critical loads, set simultaneous use, and get a planning inverter capacity range.

Add loads you want on the inverter. Surge watts matter for motors (fridge, pumps, well pumps, A/C).

Results

Continuous need
—
Surge need
—
Suggested continuous
—
Suggested surge
—
Planning range
—

Methodology

Continuous need = sum(continuous watts × quantity) × simultaneous factor. Surge need ≈ continuous need + largest (surge − continuous) adder.

Worked example

Fridge 150 W (surge 600 W) + lights 100 W, simultaneous factor 1.0 and 25% headroom → continuous need 250 W before rounding to a common inverter class.

Assumptions and limitations

Does not size DC solar input, battery C-rate or cable thickness.

Prefer critical-load panels for outages. Whole-home backup often needs far larger equipment.

FAQ

Continuous vs surge?

Continuous is steady running watts. Surge covers short motor starts.

Is this final design?

No. An installer or electrician must verify.