Battery sizing during load shedding and outages

How to size usable kWh and inverter watts for a South African home that must ride through staged outages — without treating marketing kWh as usable capacity.

Load shedding and local faults change the battery question from “how long can I run the whole house?” to “which loads must stay on, and for how many hours?” Start with a critical-load list: lights, routers, fridge/freezer, security, medical devices, and maybe a geyser or kettle only if you can afford the watt-hours. Leave non-essentials on the grid side of a changeover or transfer switch.

Marketing capacity is not usable capacity. A 5 kWh lithium pack with an 80–90% usable window and inverter/standby losses may deliver closer to 4–4.5 kWh to your loads. Divide the usable kWh you need by the average critical load in kW to get hours of cover. Two-hour Stage 4–6 windows need less energy than an overnight fault — but a fridge that cycles all night still adds up.

Inverter continuous watts must cover the simultaneous critical load; surge watts matter for motors (fridge compressors, pumps). Undersized inverters trip even when the battery still has charge. Oversized inverters waste money and idle draw. Use the battery runtime and inverter size calculators with your own watt list, then confirm earthing, COCT/municipal SSEG rules and a qualified installer before you buy.

Solar helps daytime recovery between outages more than it helps a night-only Stage 6 slot. If most shedding hits after sunset, treat PV as a recharge path for the next day, not as runtime during the event.

Next step

Open calculator

Last reviewed: 23 November 2026

Battery and inverter calculator methodology on TheSolarCalc; municipal SSEG guidance varies by metro.